Дисковый массив Infortrend F12F-G2A2-M2 12-дисков, внешний интерфейс 2x2Gb/s FC порта, интерфейс дисков FC, корпус 2U, уровни RAID: 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, 1xRAID контроллер, 1 модуль памяти 256MB, 2 модуля источников питания.
RAID
RAID- контроллер высотой 2U встраиваемый в стойку, имеет 12 корзин для жестких дисков. Одна плата контроллера. Четырех портовый FC канал со скоростью 2G (2 . внешних, 2 - внутренних). Память 256MB (SDRAM). Два блока питания с тройной системой охлаждения. Одна LCD панель. Процессор ASIC 133.
Multiple arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
Online expansion by
Adding new drives
Copying and replacing drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
Intelligent Drive Handling
In degraded mode: Skipping irreparable blocks to continue rebuild
In normal operation: Data block verification and repair
System Components
Redundant, hot-swappable components, designed for no single point of failure
2U RAID enclosure
Single RAID controller
12 drive trays
Dual redundant power supplies
2 hot-swappable fan modules
Management
Firmware-embedded Java-based GUI RAID manager
Centralized management of multiple arrays over in-band or Ethernet
Real-time event notification over Email, LAN broadcast, or SNMP traps
Auto on-lining of cascaded enclosures
SES modules on JBODs
SNMP 2.0 MIBs with get and set commands
Firmware-embedded utility via LCD keypad or RS-232C port
Drive Interface
Up to 1024 LUNs if sufficiently large memory is used with the proper settings
3.5", 1" high disk drives
12 hot-swappable drive trays
Automatic bad sector reassignment
Drive hot-swappable via SCA-II connectors
Single dual loop across 12 drives within enclosure
Host Interface
Auto-negotiate FC-AL, point-to-point, and switched fabric
Concurrent I/O commands
Tagged Command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Maintenance & Availability
Optional Li-ion battery support
Immediate array availability
Drive roaming, array configuration on drives
Auto switch cache policy and Auto shutdown
When a RAID controller detects conditions exceeding preset thresholds, the following actions will be exerted to protect the hardware:
Automatically flush cached data and switch the array's caching mode from write-back to write-through
Commence an auto shutdown
What is remarkable is all environmental thresholds associated with this mechanism are user-configurable and that caching mode changes back to write-back once normal condition is restored.
Physical/Electrical
Interfaces:
4 SFP sockets using a short-wavelength adapter
One RS-232C (Audio Jack) serial port (38400, n, 8, 1)
One RJ-45 Ethernet port
Power supply:
2 redundant, hot-swappable power supplies with PFC
Input: 90~260VAC, 47~63Hz
Output: +5V, 25A max.; +12V, 24A max.; +3.3V, 20A max.; 350watts capacity
Cooling fan
3 cooling fans in three separate modules
Operating temperature: 5 to 40°C
Non-operating temperature: - 40º to 60ºC
Relative humidity: 10~95%, non-condensing
Operating altitude: sea level to 10,000ft
Dimensions:
Chassis dimensions: 88H x 446.2W x 486.5D mm
(w/ protrusions): 88H x 481W x 525D mm
Package dimensions: 344H x 600W x 670D mm
System weight (w/o drives):
Net weight: 18kg