Новости - <h4>Дисковые массивы Infortrend на складе NStor</h4>

<h4>Дисковые массивы Infortrend на складе NStor</h4>

26.08.2008

На склад компании поступили дисковые массивы Infortrend

S16F-R1430-M5 Infortrend Fibre-SAS RAID Subsystem, 3U 16-bay rackmount, redundant controller ASIC400 with 512MB DDR RAM and BBU each, RAID6. Dual 4G-Fibre host channels, SAS drive channels, and SAS expansion ports. Redundant PSUs and redundant FANs with LCD front panel.
A16F-G2430-M2 Infortrend EonStor A16F-G2430-M2 Fibre-SATA II RAID Subsystem, 3U 16-bay rackmount, single controller ASIC400 with 256MB DDR RAM, RAID6. Dual 4G-Fibre host channels, SATA 3.0G drive channels. Redundant PSUs and redundant FANs.
S16E-G1130-M5 Infortrend iSCSI-to-SAS/SATA II, 3U-16bay rackmount, 4 x 1Gb Ethernet host channels, single controller, SAS Exp. Port, 512MB DDR, Dual PSUs, Dual Fan Modules, One LCD module
A16E-G2130-45 Infortrend iSCSI-SATA II RAID Subsystem, 3U 16-bay rackmount, single controller ASIC400 with 512MB DDR RAM, RAID6. 4 host channels Gigabit Ethernet ports, SATA 3.0G drive channels. Redundant PSUs and redundant FANs with LCD front panel.
S12S-G1033-M5 Infortrend RAID EonStor S12S-G1033-M5 SAS-SAS S12S-G1033-M5, 2U 12-bay rackmount, single controller ASIC400 with 512MB DDR RAM, RAID6. Dual SAS host channels, SAS drive channels, with SAS expansion port. Redundant PSUs and redundant FANs with LCD front panel.
S16S-G1030-M5 Infortrend SAS-SAS RAID Subsystem, 3U 16-bay rackmount, single controller ASIC400 with 512MB DDR RAM and BBU, RAID6. Dual SAS host channels (IN-OUT port for each channel, total 4 SAS ports), SAS drive channels, with SAS expansion port. Redundant PSUs and redundant FANs with LCD front panel.
S16S-R1030-M5 Infortrend EonStor (S16S-R1030-M5) SAS-SAS RAID Subsystem, 3U 16-bay rackmount, redundant controller ASIC400 with 512MB DDR RAM and BBU, RAID6. Dual SAS host channels (IN-OUT port for each channel, total 4 SAS ports), SAS drive channels, with SAS expansion port in each controller. Redundant PSUs and redundant FANs with LCD front panel.
A12S-G2130-M2 Infortrend RAID EonStor A12S-G2130-M2 SAS-SATA RAID Subsystem, 3U 16-bay rackmount, single controller ASIC400 with 512MB DDR RAM, RAID6. Dual SAS host channels (IN-OUT port for each channel, total 4 SAS ports), SATA 3.0G drive channels, no expansion port. Redundant PSUs and redundant FANs with LCD front panel.
A08U-C2411-M1 Cube Infortrend RAID EonStor A08U-C2411-M1 Cube SCSI-to-SATA II RAID subsystem, 8-bay Cube (desktop/tower convertable), Single Controller ASIC133 with 128MB SDRAM, single SCSI-320 host channel with in-out ports, Single PSU & Dual Fans
A08U-G2421-M2 Infortrend EonStor A08U-G2421-M2 SCSI-to-SATA II RAID subsystem, 2U 8-bay Rackmount, Single Controller, dual SCSI-320 host (in-out ports each CH), 256MB DDR, Dual PSUs & Fans, New 266 ASIC
A12U-G2421-M2 Infortrend SCSI-to-SATA II RAID subsystem, 2U 12-bay Rackmount, Single Controller, dual SCSI-320 host (in-out ports each CH), 256MB DDR, Dual PSUs & Triple Fans, New 266 ASIC
A16U-G2430-M2 Infortrend SCSI-SATA II RAID Subsystem, 3U 16-bay rackmount, single controller ASIC400 with 256MB DDR RAM, RAID6. Dual U320-SCSI host channels, SATA 3.0G drive channels. Redundant PSUs and redundant FANs with LCD front panel.
U12U-G4020-M2 Infortrend SCSI-to-SCSI RAID subsystem, 2U 12-bay Rackmount, Single Controller only, 4-CH SCSI-320 (2 CH for host, in-out port each CH), 256 MB DDR, Dual PSUs, Dual Fans, One LCD module, New ASIC 266

Для заказа оборудования обращайтесь в отдел систем хранения данных
По тел: (495)580-28-44
e-mail: info@raidshop.ru


Получайте новости с raidshop на почту

Системы хранения данных RaidShop.ru © 2024
Данная информация не является публичной офертой, определяемой положениями статей 435,437 Гражданского Кодекса РФ